| Two phases stepping driver |
|
|
|
|
| Name: |
YKB2608MG/H |
| Features |
| YKB2608MG/H is a constant torque high performance driver with microstep, voltage range from DC24-80V,single power input. It can match two phase hybrid step motors whose rated current under 6.0A、flange size range from 57-86mm.
Owe to bipolar constant current chopper control of the driver circuit, the motor can run smoothly and hardly has any noise. Rising the voltage can greatly improve high speed performance and output torque of the motor. Once the pulse stops for 100ms,the phase current will automatically cut by half, which can reduce chances of overheat. Users can operate the driver with microstep in low speed occasion.The upmost microstep can be set to 200. |
|
|
|
|
|
|
|
|
Feature:
- High performance, low price;
- Provides 12/8 kinds microstep selection,upmost microstep can be set to 200x.
- Special circuit design,reduce noise, enhance steadiness.
- The upmost pulse response frequence amounts to 200Kpps;
- Once the pulse stops for 100ms,phase current automatically cut by half.
- Bipolar constant current chopper control;
- Photocoupler isolated input/output;
- Adjustable drive current range from 0.5A/phase-6.0A/phase;
- Single power input, voltage range from DC24-80V;
- Overheat protection&Overcurrent, under voltage protection;
- Dimension:45x136x92mm,Net Weight:0.5kg.
YKB2608MG Microstep setting YKB2608MH Microstep setting

Terminal Assignment

Running current setting Installation dimensions(mm)

Function setting Input signal timing diagram

Driver Connection

Caution
1. Do not reverse the power input,input voltage should not exceed DC80V.
2. Input logic should be 5V,otherwise it should connect a resistor.
3.Due to the special control circuit, this module for 4 leads or 6 leads or 8 leads step motors.
4. O.H is malfunction indicator. Once the driver temperature exceeds 70°C,the current will be cut off automatically and the driver will resume working till the temperature drops to 50°C. If this happens,please install ventilation equipment.
5. Once over current (short circuit)/under voltage occur, LED O.C lights, please shut off power and check the electricity circuit to solve the problem, then restore power supply
6. PWR is power indicator,it lights when power on.
7. Passing the origin or there is pulse output, TM LED lights.
|
|